Lab Report #1: Tensile Testing  Name: Matt Turner Date Submitted: 12/20/07 Section 10-12 Thursday Group Members: 1. Ray Casper 2. John Matthews Title: Tensile Testing of Al-Cu Alloy 2024 T3 Equipment : Tinius Olsen Electromatic 120 kips Universal Tester  Tinius Olsen Extensometer LS-20%-2B Specimen : Al-Cu Alloy 2024 T3 Abstract A tensile test was performed on a standard 0.5” round specimen of Al-Cu Alloy 2024 T3. The extensometer was taken off when strain reached ~4%. The experimental results show an elastic modulus of 9954916 psi, which is 6.1% lower than the accepted value. The 0.2% offset yield strength, tensile strength, %elongation to failure, and %reduction in area values are 53197 psi, 76130 psi , 18% and 21% respectively. Each of these values exceeded the minimum specified for this alloy of aluminum, and is therefore acceptable. The fracture surface almost shows the typical cup and cone ductile failure, as expected. All in all, the experiment was a success, yielding expected results.
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
L 0 D 0 D f L f A 0 A f P max P break Em Length Diameter Diameter Length Area Area Max Load BreakLoad Modulus 1.997 0.500 0.445 2.355 0.196 0.156 14948 10231 9954916 in in in in in 2 in 2 lb lb psi Toughness Modulus 1.192E+04 Converted Data Corrected Data Engg. Stress-Strain True Stress-Strain 0.2% Offset Area under the Curve % lb % lb in/in psi in/in psi psi in/in psi psi Strain Load Strain Load Strain Stress Strain Stress Stress Width Height Area 0.0198 259 0.0000 0 0 0 0.000 0 0.0243 355 0.0045 96 4.456E-05 486.3927 4.455E-05 486.4144 4.456E-05 243.1964 1.08E-02 0.0310 484 0.0112 224 1.119E-04 1143.116 1.119E-04 1143.244 6.733E-05 814.7544 5.49E-02 0.0332 519 0.0134 259 1.336E-04 1319.479 1.335E-04 1319.655 2.167E-05 1231.298 2.67E-02 0.0349 544 0.0150 285 1.503E-04 1451.159 1.503E-04 1451.377 1.678E-05 1385.319 2.32E-02 0.0387 621 0.0189 361 1.885E-04 1838.921 1.885E-04 1839.267 3.821E-05 1645.04 6.29E-02 0.0417 674 0.0219 414 2.186E-04 2110.472 2.186E-04 2110.933 3.011E-05 1974.696 5.95E-02 0.0422 697 0.0224 437 2.236E-04 2226.601 2.236E-04 2227.099 4.980E-06 2168.536 1.08E-02 0.0477 795 0.0278 536 2.785E-04 2728.216 2.784E-04 2728.976 5.483E-05 2477.408 1.36E-01 0.2229 4265 0.2031 4005 2.031E-03 20398.39 2.029E-03 20439.82 310.4666 1.709E-04 19509.43 3.33E+00 0.2405 4608 0.2207 4348 2.207E-03
Background image of page 2
Image of page 3
This is the end of the preview. Sign up to access the rest of the document.

Page1 / 6

Lab 1 - Lab Report#1 Tensile Testing Date Submitted Group...

This preview shows document pages 1 - 3. Sign up to view the full document.

View Full Document Right Arrow Icon
Ask a homework question - tutors are online