Example 7-2 A heat pump with an ideal compressor operates between 0.2 MPa and 1 MPa. R134a flows through the system at a rate of 0.3 kg/s. The heat pump is used to heat a home that loses heat to the environment at a rate of 180,000 Btu/hr. Refrigerant leaves the compressor as a subcooled liquid. a) Draw a T-s diagram b) Find the temperature of R134a leaving the condenser c) Find the rate of heat transfer in the evaporator, in kW d) Find COP Solution: b) The first law for the condenser is () 23 HR Qm h h =− ± ± To find h 2 , use the second law on the compressor: 12 s s =
Background image of page 1

Info iconThis preview has intentionally blurred sections. Sign up to view the full version.

View Full DocumentRight Arrow Icon
1 kJ entropy(R134a, 200, 1) 0.9377 kg K sP x == = = 22 kJ enthalpy(R134a, 1000,