Side the clearance between the installed rack

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm). CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. Rack Kit HP P4000 G2 rack models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36". Telco Rack Support Support for all 2 and 4 post Telco racks and threaded hole racks requires an additional option kit from Rack Solutions. The Rack Solutions brackets can be purchased at: www.hp.com/go/rackandpower. NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. DA - 13552 Worldwide — Version 6 — August 6, 2010 Page 32 QuickSpecs HP StorageWorks P4000 G2 SAN Solutions Technical Specifications P4300 P4300 MDL SAS Starter SAN P4300 SAS P4500 P4500 Starter SAN Virtualization Multi-Site SAN SAN Dimensions 4U 6.9 x 17.64 x 28.23 in (17.52 x 44.80 x 71.71 cm) Weight P4500 P4300 P4500 P4800 Scalable Storage Storage BladeSystem Capacity System System SAN* SAN 8U 10U 2U 20U 13.8 x 17.25 x 17.25 x 17.64 x 17.64 x 17.64 x 3.45 x 17.64 x 28.23 28.23 in 28.23 in 35.08 in in (8.76 x 44.80 x (35.04 x (43.8 x (43.80 x 71.71 cm) 44.80 x 44.80 x 44.80 x 71.71 cm) 71.71 cm) 89.12 cm) 90 lbs/ 180 lbs/ 225 lbs/ 38.0 lbs/ 40.82 kg 81.64 kg 102.05 kg 17.23 kg Redundant Hot-Plug Common Slot Power Supplies Power/Cooling Auto-switching universal 115/220 Volts 5.3 belsA-weighted 4996 4205 709 @115V 1418 BTU/hr 1760 BTU/hr 2248 BTU/hr BTU/hr BTU/hr BTU/hr 416 watts 524 watts 658 watts 1316 watts 1230 watts 208 watts 4428 4130 697 @220V 1394 BTU/hr 1788 BTU/hr 2214 BTU/hr BTU/hr BTU/hr BTU/hr 408 watts 516 watts 648 watts 1296 watts 1210 watts 204 watts Environmental 76 lbs/ 34.46 kg 45.0 lbs/ 20.41 kg 841 BTU/hr 246 watts 826 BTU/hr 242 watts 892.3 lbs/ 404.75 kg Dependent upon final C7000 Enclosure Config. System Inlet Temperature Operating Relative Humidity (noncondensing) Altitude 10° to 35°C (50° to 95°F) at sea level with an altitude Derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level t...
View Full Document

This document was uploaded on 01/20/2014.

Ask a homework question - tutors are online