Several factors affect the degree of injury including

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: njury, including skin color, area of skin exposed, and type of clothing worn. Proper clothing, work distances, and overcurrent protection can reduce the risk of such a burn. (2) A high-voltage arc can produce a considerable pressure wave blast. A person 2 feet away from a 25,000-amp arc feels a force of about 480 pounds on the front of the body. In addition, such an explosion can cause serious ear damage and memory loss due to Page 12 Section 3 concussion. Sometimes the pressure wave throws the victim away from the arc-blast. While this may reduce further exposure to the thermal energy, serious physical injury may result. The pressure wave can propel large objects over great distances. In some cases, the pressure wave has enough force to snap off the heads of steel bolts and knock over walls. (3) A high-voltage arc can also cause many of the copper and aluminum components in electrical equipment to melt. These droplets of molten metal can be blasted great distances by the pressure wave. Although these droplets harden rapidly, they can still be hot enough to cause serious burns or cause ordinary clothing to catch fire, even if you are 10 feet or more away. ive technicians were performing preventive maintenance on the electrical system of a railroad maintenance facility. One of the technicians was assigned to clean the lower compartment of an electrical cabinet using cleaning fluid in an aerosol can. But, he began to clean the upper compartment as well. The upper compartment was filled with live circuitry. When the cleaning spray contacted the live circuitry, a conductive path for the current was created. The current passed through the stream of fluid, into the technician's arm, and across his chest. The current caused a loud explosion. Co-workers found the victim with his clothes on fire. One worker put out the fire with an extinguisher, and another pulled the victim away from the compartment with a plastic vacuum cleaner hose. The paramedics responded in 5 minutes. Although the victim survived the shock, he died 24 hours later of burns. This death could have been prevented if the following precautions had been taken: Before doing any electrical work, de-energize all circuits and equipment, perform lock-out/tag-out, and test circuits and equipment to make sure they are de-energized. The company should have trained the workers to perform their jobs safely. Proper personal protective equipment (PPE) should always be used. Never use aerosol spray cans around high-voltage equipment. F Thermal burns may result if an explosion occurs when electricity ignites an explosive mixture of material in the air. This ignition can result from the buildup of combustible vapors, gases, or dusts. Occupational Safety and Health Administration (OSHA) standards, National Fire Protection Association (NFPA) standards, and other safety standards give precise safety requirements for the operation of electrical systems and equipment in such dangerous areas. Ignition can also be caused by overheated conductors or equipment, or by normal arcing at switch contacts or in circuit breakers. OSHA--Occupational Safety and Health Administration--the Federal agency in the U.S. Department of Labor that establishes and enforces workplace safety and health regulations Section 3 Page 13 B U r N S C AU S E D B Y E L E C T r I C I T Y Electrical Fires Electricity is one of the most common causes of fires and thermal burns in homes and workplaces. Defective or misused electrical equipment is a major cause of electrical fires. If there is a small electrical fire, be sure to use only a Class C or multipurpose (ABC) fire extinguisher, or you might make the problem worse. All fire extinguishers are marked with letter(s) that tell you the kinds of fires they can put out. Some extinguishers contain symbols, too. The letters and symbols are explained below (including suggestions on how to remember them). A B C Here are a couple of fire extinguishers at a worksite. Can you tell what types of fires they will put out? (think: Ashes) = paper, wood, etc. (think: Barrel) = flammable liquids (think: Circuits) = electrical fires This extinguisher can only be used on Class B and Class C fires. Learn how to use fire extinguishers at work. This extinguisher can only be used on Class A and Class C fires. However, do not try to put out fires unless you have received proper training. If you are not trained, the best thing you can do is evacuate. Section 3 Page 14 Summary of Section 3 Burns are the most common injury caused by electricity. The three types of burns are electrical burns, arc burns, and thermal contact burns. All fire extinguishers are marked with a letter(s), which identifies the kinds of fires they put out. Sometimes the label is marked with both a letter and symbol. Be sure to read the label and use the appropriate extinguisher. Section 3 Page 15 First Aid Fact Sheet What Should I Do If a Co-Worker Is Shocked or Burned by Electricity? Shut off the electrical current if the victim is still in contact with t...
View Full Document

Ask a homework question - tutors are online