Morrison michigan tech u system head meb written on

Info iconThis preview shows page 1. Sign up to view the full content.

View Full Document Right Arrow Icon
This is the end of the preview. Sign up to access the rest of the document.

Unformatted text preview: h U. System Head - MEB written on total system, excluding pump ≡ Δ Δ 2 DEMAND Δ 2 , Δ , , 10 © Faith A. Morrison, Michigan Tech U. 5 Pumping System Head CM3215 FAM 3Mar2014 Friction in Fittings, Straight Pipe: Data Correlations from Literature Δ , , These have been measured and correlated in the literature as a function of flow rate through Fanning friction factor Re (straight pipes) and (fittings) Δ , , 4 Note: if diameter changes, 〈 〉 changes; thus we need separate calculations for every 〈 〉 2 11 © Faith A. Morrison, Michigan Tech U. Data correlation for friction factor Δ versus Re (flow rate) in a pipe 16 Re Moody Chart (Geankoplis) 12 © Faith A. Morrison, Michigan Tech U. 6 Pumping System Head CM3215 FAM 3Mar2014 Reference: Morrison, Faith A, An Introduction to Fluid Mechanics, Cambridge University Press, 2013, Figure 7.18, page 532. 13 © Faith A. Morrison, Michigan Tech U. System Head - MEB written on total system, excluding pump DEMAND 2 , Some terms go as , 4 2 (slight additional dependence) 14 © Faith A. Morrison, Michigan Tech U. 7 Pu...