0AZIMUTH 00 AHU OPERATING HOURS 6AM TO MIDN CALCS BASED ON 24 HOURS OPERATION

0azimuth 00 ahu operating hours 6am to midn calcs

This preview shows page 100 - 103 out of 131 pages.

(SUN POSITION ~ ALTITUDE = 0.0 AZIMUTH = 0.0) AHU OPERATING HOURS 6AM TO MIDN. CALCS BASED ON 24 HOURS OPERATION FROM 6AM SOLAR AND TRANSMISSION GAINS WALLS AND ROOFS (Using light wt roof data) No SUN EXPOSE S.DENS ABS AREA T-DIFF UVALUE ROOM ___________________________________________________________ #1 OFF 30.0 (222 0.50) 60.00 2.0 0.38 100% = 46 TRANSMISSION GAIN EXCEPT WALLS AND ROOFS No ITEM AREA T-DIFF UVALUE ROOM _____ ____ ________________________ FLOOR 250.00 9.8 0.67 = 1641 INTERNAL HEAT GAIN PEOPLE (ACTIV = 4) 71.4 70. 100% = 5000 LIGHTS (FLE 420 kg/m2) 250.0 35.00 0.99 100% = 8663 _______ ROOM SENSIBLE HEAT = 15350 _____ ADJUSTED ROOM SENSIBLE HEAT = 15350 LATENT HEAT GAIN PEOPLE (ACTIV = 4) 71.4 60. 100% = 4286 _____ ROOM LATENT HEAT = 4286 _____ ADJUSTED ROOM LATENT HEAT = 4286 AHU 12 AHU-8, Zone 1, Rm 1 Shop-106
Image of page 100
ROOM COOLING LOAD CHART AT 11PM JAN (SUN POSITION ~ ALTITUDE = 0.0 AZIMUTH = 0.0) AHU OPERATING HOURS 6AM TO MIDN. CALCS BASED ON 24 HOURS OPERATION FROM 6AM SOLAR AND TRANSMISSION GAINS WALLS AND ROOFS (Using light wt roof data) No SUN EXPOSE S.DENS ABS AREA T-DIFF UVALUE ROOM ___________________________________________________________ #1 OFF 210.0 (222 0.50) 60.00 1.9 0.38 100% = 44 TRANSMISSION GAIN EXCEPT WALLS AND ROOFS No ITEM AREA T-DIFF UVALUE ROOM _____ ____ ________________________ FLOOR 250.00 9.8 0.67 = 1641 INTERNAL HEAT GAIN PEOPLE (ACTIV = 4) 71.4 70. 100% = 5000 LIGHTS (FLE 420 kg/m2) 250.0 35.00 0.99 100% = 8663 _______ ROOM SENSIBLE HEAT = 15348 _____ ADJUSTED ROOM SENSIBLE HEAT = 15348 LATENT HEAT GAIN PEOPLE (ACTIV = 4) 71.4 60. 100% = 4286 _____ ROOM LATENT HEAT = 4286 _____ ADJUSTED ROOM LATENT HEAT = 4286 AHU 12 AHU-8, Zone 1, Rm 2 Shop-107 ROOM COOLING LOAD CHART AT 11PM JAN (SUN POSITION ~ ALTITUDE = 0.0 AZIMUTH = 0.0) AHU OPERATING HOURS 6AM TO MIDN. CALCS BASED ON 24 HOURS OPERATION FROM 6AM SOLAR AND TRANSMISSION GAINS WALLS AND ROOFS (Using light wt roof data) No SUN EXPOSE S.DENS ABS AREA T-DIFF UVALUE ROOM ___________________________________________________________ #1 OFF 210.0 (222 0.50) 60.00 1.9 0.38 100% = 44 TRANSMISSION GAIN EXCEPT WALLS AND ROOFS No ITEM AREA T-DIFF UVALUE ROOM _____ ____ ________________________ FLOOR 250.00 9.8 0.67 = 1641 INTERNAL HEAT GAIN PEOPLE (ACTIV = 4) 71.4 70. 100% = 5000 LIGHTS (FLE 420 kg/m2) 250.0 35.00 0.99 100% = 8663 _______ ROOM SENSIBLE HEAT = 15348 _____ ADJUSTED ROOM SENSIBLE HEAT = 15348 LATENT HEAT GAIN PEOPLE (ACTIV = 4) 71.4 60. 100% = 4286 _____ ROOM LATENT HEAT = 4286 _____
Image of page 101
ADJUSTED ROOM LATENT HEAT = 4286 AHU 12 AHU-8, Zone 1, Rm 3 Shop-108 ROOM COOLING LOAD CHART AT 11PM JAN (SUN POSITION ~ ALTITUDE = 0.0 AZIMUTH = 0.0) AHU OPERATING HOURS 6AM TO MIDN. CALCS BASED ON 24 HOURS OPERATION FROM 6AM SOLAR AND TRANSMISSION GAINS WALLS AND ROOFS (Using light wt roof data) No SUN EXPOSE S.DENS ABS AREA T-DIFF UVALUE ROOM ___________________________________________________________ #1 OFF 210.0 (222 0.50) 60.00 1.9 0.38 100% = 44 TRANSMISSION GAIN EXCEPT WALLS AND ROOFS No ITEM AREA T-DIFF UVALUE ROOM _____ ____ ________________________ FLOOR 250.00 9.8 0.67 = 1641 INTERNAL HEAT GAIN PEOPLE (ACTIV = 4) 71.4 70. 100% = 5000 LIGHTS (FLE 420 kg/m2) 250.0 35.00 0.99 100% = 8663 _______ ROOM SENSIBLE HEAT = 15348 _____ ADJUSTED ROOM SENSIBLE HEAT = 15348 LATENT HEAT GAIN PEOPLE (ACTIV = 4) 71.4 60. 100% = 4286 _____ ROOM LATENT HEAT = 4286 _____ ADJUSTED ROOM LATENT HEAT = 4286 AHU 12 AHU-8, Zone 1, Rm 4 Shop-109 ROOM COOLING LOAD CHART AT 11PM JAN (SUN POSITION ~ ALTITUDE = 0.0 AZIMUTH = 0.0) AHU OPERATING HOURS 6AM TO MIDN. CALCS BASED ON 24 HOURS OPERATION FROM 6AM SOLAR AND TRANSMISSION GAINS WALLS AND ROOFS (Using light wt roof data) No SUN EXPOSE S.DENS ABS AREA T-DIFF UVALUE ROOM ___________________________________________________________ #1 OFF 210.0 (222 0.50) 60.00 1.9 0.38 100% = 44 TRANSMISSION GAIN EXCEPT WALLS AND ROOFS No ITEM AREA T-DIFF UVALUE ROOM _____ ____ ________________________ FLOOR 250.00 9.8 0.67 = 1641 INTERNAL HEAT GAIN PEOPLE (ACTIV = 4) 71.4 70. 100% = 5000 LIGHTS (FLE 420 kg/m2) 250.0 35.00 0.99 100% = 8663 _______ ROOM SENSIBLE HEAT = 15348 _____ ADJUSTED ROOM SENSIBLE HEAT = 15348 LATENT HEAT GAIN PEOPLE (ACTIV = 4) 71.4 60. 100% =
Image of page 102
Image of page 103