Figure ## Sacristy – Daytime – Working Plane – Isolines Figure ## Sacristy – Daytime – Working Plane – False Colors Figure ## Sacristy – Daytime – Working Plane – Value Chart Figure ## Display Control Room – Daytime with All Luminaire Groups Off – Working Plane – Combined Data When simulated under similar conditions except that no luminaires were turned on, the room was only able to achieve 236 lux which is below the standard of 300 lux. Therefore, there is a need for luminaires to be turned on during the day. Although large amount of sunlight enters the room through the windows, it is not enough to light the entire room up to the standard levels. At the center of the room, values of only 40 to 90 lux were observed which greatly improved to between 260 and 330 lux when luminaire group three was turned on. Areas near the front doors were also lower ranging from 70 to 90 lux and greatly improved to between 160 to 250 lux. ii. Floor Plane Figure ## Sacristy – Daytime – Floor Plane – Combined Data 1 Figure ## Sacristy – Daytime – Floor Plane – Combined Data 2
Image of page 14
UST: EE524L-T2AY1920-5EEB-G6 15 The room floor plane was able to reach an average level of 174 lux. Although below standard, it was observed that the walking areas were able to reach levels of 200 to 300 lux which is ample enough for walking and avoid hitting something. Uniformity can also be observed withing the walking areas so the eyes will not get tired with adjusting when walking. Figure ## Sacristy – Daytime – Floor Plane – Isolines Figure ## Sacristy – Daytime – Floor Plane – False Colors Figure ## Sacristy– Daytime – Floor Plane – Value Chart Figure ## Display Control Room – Daytime with All Luminaire Groups Off – Floor Plane – Combined Data Similar to the working plane, lower values were observed when all the luminaire groups were turned off which can result to uncomfortable walking and eye strain as the eyes are trying to see what is there in the vicinity of your walking area. d. Nighttime Data Figure ## Sacristy – Nighttime – 3D Render 1 Figure ## Sacristy – Nighttime – 3D Render 2 Figure ## Sacristy – Nighttime – Room – False Color 1 Figure ## Sacristy – Nighttime – Room – False Color 2 i. Working Plane
Image of page 15
UST: EE524L-T2AY1920-5EEB-G6 16 Figure ## Sacristy – Nighttime – Working Plane – Combined Data 1 Figure ## Sacristy – Nighttime – Working Plane – Combined Data 2 Nighttime was simulated at 8:00 PM as usually the last mass ends at this time and the sun is completely out. The room was still able to reach an average value of 311 lux which means the room was able to reach the standards with its luminaires. Empty areas were able to achieve values of more than 400 lux as they area directly below luminaires five and six which has the greatest luminous flux. Values were then gradually decreasing to the standard of around 300 lux at the center area where most activities were made during the night such as preparing for the mass and where the couches are located for resting.
Image of page 16
Image of page 17

You've reached the end of your free preview.

Want to read all 25 pages?

  • Spring '18
  • Kenneth Sinson
  • ii. Floor Plane, luminaire group

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture