• You do this Set-Up by focussing on the Specimen (or the "P" Slide) using the Fine and Coarse Focus Knobs, which raise and lower the Stage without moving the Condenser.
We have textbook solutions for you!
The document you are viewing contains questions related to this textbook.
Understanding Health Insurance: A Guide to Billing and Reimbursement
The document you are viewing contains questions related to this textbook.
Chapter 7 / Exercise 6
Understanding Health Insurance: A Guide to Billing and Reimbursement
Green
Expert Verified
MIC 103L Exam 1 Page 810. The Second Set-Up (Set-Up 2) for Brightfield Alignment involves -- A. • Setting the Working Distance between Specimen and the Condenser Lens. • You do this Set-Up by focussing on the Image of the Field Diaphragm using the Condenser Focus Knob, which raises and lowers both the Condenser and the Stage in Tandem. ________________________________________________ B. • Setting the Working Distance between Specimen and the Condenser Lens. • You do this Set-Up by focussing on the Image of the Field Diaphragm using the Condenser Focus Knob, which raises and lowers the Condenser without moving the Stage. ________________________________________________ C. • Setting the Working Distance between the Specimen and the Objective Lens. • You do this Set-Up by focussing on the Specimen (or the "P" Slide) using the Fine and Coarse Focus Knobs, which raise and lower both the Stage and the Condenser in Tandem. ________________________________________________ D. • Setting the Working Distance between the Specimen and the Objective Lens. • You do this Set-Up by focussing on the Specimen (the the "P" Slide) using the Fine and Coarse Focus Knobs, which raise and lower the Stage without moving the Condenser. ______________________________________________________________________________________________________________________________________ STOP! • Perform a Self-Diagnostic for any Evidence of Sudden-Onset Idiopathic Anal-Cranial Inversion. • Did you just answer Question Ten (10) on this Page? • Then you are cleared to answer Question Eleven (11) on Page 9. ______________________________________________________________________________________________________________________________________
MIC 103L Exam 1 Page 911. The Third Set-Up (Set-Up 3) for Brightfield Alignment involves -- A. • Centering and trimming the Cylinder of Light projected by the Condenser into the Objective Lens. - You use the Fine Focus Knob to touch-up the Focus of the Image of the Condenser Diaphragm. - You use the Condenser Diaphragm Control to adjust the Size of the Image of the Condenser Diaphragm. - You use the Condenser Centering Screws to center the Image of the Condenser Diaphragm. _______________________________ B. • Centering and trimming the Cylinder of Light projected by the Condenser into the Objective Lens. - You use the Fine Focus Knob to touch-up the Focus the Image of the Field Diaphragm. - You use the Condenser Diaphragm Control to adjust the Size of the Image of the Field Diaphragm. - You use the Mechanical State Controls to center the Image of the Field Diaphragm. _______________________________ C. • Centering and trimming the Cylinder of Light projected by the Illuminator into the Condenser Lens. - You use the Condenser Focus Knob to touch-up the Focus of the Image of the Field Diaphragm. - You use the Field Diaphragm Control on the Illuminator to adjust the Size of the Image of the Field Diaphragm - You use the Condenser Centering Screws to center the Image of the Field Diaphragm. _______________________________ D. • Centering and trimming the Cylinder of Light projected by the Illuminator into the Condenser Lens. - You use the Condenser Focus Knob to touch-up the Focus of the Image of the Condenser Diaphragm. - You use the Condenser Diaphragm Control on the Condenser to adjust the Size of the Image of the Condenser Diaphragm - You use the Condenser Centering Screws to center the Image of the Condenser Diaphragm.
MIC 103L Exam 1 Page 10