At Speed Stop with On delay from F063 14 Ground Fault Trip 30 At Speed End of

At speed stop with on delay from f063 14 ground fault

This preview shows page 31 - 33 out of 36 pages.

At Speed / Stop with On-delay from F063 14 Ground Fault Trip 30 At Speed / End of Decel with On-delay from F063 15 Phase Rotation Trip 31 Start / End of Decel with On-delay from F063 16 Voltage Imbalance Trip 32 Power Loss (nCP No Control Power) Trip *Note: Flash rate for Setting #23 is ½ second On and Off
Background image
Basic Installation and Operation GuideVMX2 Series Digital Solid State Soft Starters 18 1250AVMX2 Quick Setup Guide 32 | P a g eFault Mode The VMX2 Series will automatically enter the Fault Mode when a fault occurs in the motor or starter and display a code indicating the condition that caused a shutdown. Fault codes are three-digits in length and are displayed in alpha characters. The first and second characters (reading left to right) are the initials for the applicable English-language fault name. The third or right-most character can be either A, c, or d to denote when the fault occurred. Adenotes Acceleration. “c”denotes Constant speed. “d”denotes Decel or Stopped. A Fault History of the past 3 events is stored and can be accessed by using the Up or Down Arrow keys before pressing the Reset button. The first (newest) event is indicated by the decimal point in the lower right corner. A more detailed history with time and date stamps is also kept in Functions 85 through 93. Fault Codes:Basic common fault codes are shown in the chart below. For additional details refer to Chapter 7 of the Advanced Installation, Operation and Programming Manual, or contact the factory for assistance. Fault Condition DescriptionFault Display CodeReadoutFault Number Code used in History, F085, F088 and F091LED IndicatorOver Current during Accel; Const spd; Decel ocA; occ: ocd 1; 2; 3 Over Current Phase Loss during Accel; Const spd; Decel PLA; PLc; PLd 4; 5; 6 Phase Loss Over Temperature during Accel; Const spd; Decel otA; otc; otd 7; 8; 9 Over Temp Over Load during Accel; Const spd; Decel oLA; oLc; oLd 10; 11; 12 Over Load Shorted SCR during Accel; Const spd; Decel SSA; SSc; SSd 13; 14; 15 Shorted SCR Shunt Trip during Accel; Const spd; Decel st 16; 17; 18 Shunt Trip Current Imbalance during Accel; Const spd; Decel IbA; Ibc; Ibd 19; 20; 21 --- Under Current during Accel; Const spd; Decel UcA; Ucc; Ucd 22; 23; 24 --- Short Circuit during Accel; Const spd; Decel ScA; Scc; Scd 25; 26; 27 Over Current Ground Fault during Accel; Const spd; Decel GFA; GFc; GFd 28; 29; 30 --- Bypass Discrepancy during Accel; Const spd; Decel bPA; bPc; bPd 31; 32; 33 --- External Lockout Trip during Accel; Const spd; Decel LcA; lcc; Lcd 34; 35; 36 Over Load Rotation Trip during Accel; Const spd; Decel rtA; rtc; rtd 37; 38; 39 --- Voltage Imbalance during Accel; Const spd; Decel EIA;EIC;EID 40;41;42 N/A Over Voltage during Accel; Const spd; Decel OEA;OEC;OED 43;44;45 Under Voltage during Accel; Const spd; Decel UEAlUEC;UED 46;47;48 Power Factor during Accel; Const spd; Decel PFA;PFC;PFD 49;50;51 PowerR during Accel; Const spd; Decel PRA;PRC;PRD 52;53;54 Control Power Loss during Accel; Const spd; Decel nCPA, nCPC, nCPD 55;56;57 Additional codes that may be displayedDisplay CodeReadoutCondition DescriptionnFLANo Full Load Amps set in F001InhInhibit:
Background image
Image of page 33

You've reached the end of your free preview.

Want to read all 36 pages?

  • Winter '18
  • mr. j
  • Relay, BYPASS CONTACTOR

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture