This section describes the procedure for turning on the power to a physical partitionto which the PCI expansion unit requiring maintenance belongs. How the modeswitch is changed depends on the connection destination.1.Change the mode switch on the operation panel to Locked mode.- When the connection destination is a SPARC M10-1/M10-4Switch the mode switch to Locked mode.- When the connection destination is a SPARC M10-4S (without the crossbarbox)Switch the mode switches of BB-ID#00 and #01 to Locked mode.- When the connection destination is a SPARC M10-4S (with the crossbar box)Switch the mode switches of BB-ID#80 and #81 to Locked mode.2.Log in to the XSCF shell.3.Execute the poweron command to power on the stopped physical partition.In the following example, PPAR-ID 00 is specified.Enter the PPAR-ID you previously noted by using the showboards command.Chapter 6Understanding the Preparations for Restoring the System55
XSCF>showstatusXSCF>showhardconfSPARCM10-4S;+Serial:2081229003;Operator_Panel_Switch:Service;+System_Power:On;System_Phase:CabinetPowerOn;Partition#0PPAR_Status:Running;BB#00Status:Normal;Role:Master;Ver:2050h;Serial:2081229003;+FRU-Part-Number:CA07361-D202A0;+Power_Supply_System:;+Memory_Size:320GB;------------------------snip------------------------PCI#0Status:Normal;Name_Property:pci;+Vendor-ID:108e;Device-ID:9020;+Subsystem_Vendor-ID:0000;Subsystem-ID:0000;+Model:;+Connection:7001;PCIBOX#7001;Status:Normal;Ver:1110h;Serial:2121237001;+FRU-Part-Number:;IOBStatus:Normal;Serial:PP123403JE;+FRU-Part-Number:CA20365-B66X008AG;LINKBOARDStatus:Normal;Serial:PP1234026P;+FRU-Part-Number:CA20365-B60X001AA;PCI#1Name_Property:ethernet;+Vendor-ID:1077;Device-ID:8000;+Subsystem_Vendor-ID:1077;Subsystem-ID:017e;+Model:;------------------------snip------------------------4.Execute the showstatus command to confirm that the FRU is operatingnormally after the completion of maintenance.Nothing is displayed in the normal state.5.Execute the showhardconf command to check the hardware configurationand the status of each component.6.3Starting the Entire SystemThis section explains the procedure for starting the system. The operation for startingthe system is performed on the server.Start the system in either of the following two ways:■Starting the system with the XSCF command■Starting the system from the operation panel1.Check that the XSCF STANDBY LED on the operation panel is on.PCI Expansion Unit for Fujitsu M10/SPARC M10 Systems Service Manual・December 201356
Note -When Oracle Solaris is configured to start automatically, use the sendbreak commandof the XSCF shell to display the ok prompt. This should be done after the display consolebanner appears, but before the system starts Oracle Solaris.XSCF>showstatusXSCF>showhardconfSPARCM10-4S;+Serial:2081229003;Operator_Panel_Switch:Service;+System_Power:On;System_Phase:CabinetPowerOn;Partition#0PPAR_Status:Running;BB#00Status:Normal;Role:Master;Ver:2050h;Serial:2081229003;+FRU-Part-Number:CA07361-D202A0;+Power_Supply_System:;+Memory_Size:320GB;------------------------snip------------------------PCI#0Status:Normal;Name_Property:pci;+Vendor-ID:108e;Device-ID:9020;+Subsystem_Vendor-ID:0000;Subsystem-ID:0000;+Model:;+Connection:7001;PCIBOX#7001;Status:Normal;Ver:1110h;Serial:2121237001;+FRU-Part-Number:;IOB