This section describes the procedure for turning on the power to a physical partition to which the PCI expansion unit requiring maintenance belongs. How the mode switch is changed depends on the connection destination. 1. Change the mode switch on the operation panel to Locked mode. - When the connection destination is a SPARC M10-1/M10-4 Switch the mode switch to Locked mode. - When the connection destination is a SPARC M10-4S (without the crossbar box) Switch the mode switches of BB-ID#00 and #01 to Locked mode. - When the connection destination is a SPARC M10-4S (with the crossbar box) Switch the mode switches of BB-ID#80 and #81 to Locked mode. 2. Log in to the XSCF shell. 3. Execute the poweron command to power on the stopped physical partition. In the following example, PPAR-ID 00 is specified. Enter the PPAR-ID you previously noted by using the showboards command. Chapter 6 Understanding the Preparations for Restoring the System 55
Image of page 71
XSCF> showstatus XSCF> showhardconf SPARC M10-4S; + Serial:2081229003; Operator_Panel_Switch:Service; + System_Power:On; System_Phase:Cabinet Power On; Partition#0 PPAR_Status:Running; BB#00 Status:Normal; Role:Master; Ver:2050h; Serial:2081229003; + FRU-Part-Number:CA07361-D202 A0 ; + Power_Supply_System: ; + Memory_Size:320 GB; ------------------------ snip ------------------------ PCI#0 Status:Normal; Name_Property:pci; + Vendor-ID:108e; Device-ID:9020; + Subsystem_Vendor-ID:0000; Subsystem-ID:0000; + Model:; + Connection:7001; PCIBOX#7001; Status:Normal; Ver:1110h; Serial:2121237001; + FRU-Part-Number:; IOB Status:Normal; Serial:PP123403JE ; + FRU-Part-Number:CA20365-B66X 008AG ; LINKBOARD Status:Normal; Serial:PP1234026P ; + FRU-Part-Number:CA20365-B60X 001AA ; PCI#1 Name_Property:ethernet; + Vendor-ID:1077; Device-ID:8000; + Subsystem_Vendor-ID:1077; Subsystem-ID:017e; + Model:; ------------------------ snip ------------------------ 4. Execute the showstatus command to confirm that the FRU is operating normally after the completion of maintenance. Nothing is displayed in the normal state. 5. Execute the showhardconf command to check the hardware configuration and the status of each component. 6.3 Starting the Entire System This section explains the procedure for starting the system. The operation for starting the system is performed on the server. Start the system in either of the following two ways: Starting the system with the XSCF command Starting the system from the operation panel 1. Check that the XSCF STANDBY LED on the operation panel is on. PCI Expansion Unit for Fujitsu M10/SPARC M10 Systems Service Manual December 2013 56
Image of page 72
Note - When Oracle Solaris is configured to start automatically, use the sendbreak command of the XSCF shell to display the ok prompt. This should be done after the display console banner appears, but before the system starts Oracle Solaris. XSCF> showstatus XSCF> showhardconf SPARC M10-4S; + Serial:2081229003; Operator_Panel_Switch:Service; + System_Power:On; System_Phase:Cabinet Power On; Partition#0 PPAR_Status:Running; BB#00 Status:Normal; Role:Master; Ver:2050h; Serial:2081229003; + FRU-Part-Number:CA07361-D202 A0 ; + Power_Supply_System: ; + Memory_Size:320 GB; ------------------------ snip ------------------------ PCI#0 Status:Normal; Name_Property:pci; + Vendor-ID:108e; Device-ID:9020; + Subsystem_Vendor-ID:0000; Subsystem-ID:0000; + Model:; + Connection:7001; PCIBOX#7001; Status:Normal; Ver:1110h; Serial:2121237001; + FRU-Part-Number:; IOB
Image of page 73
Image of page 74

You've reached the end of your free preview.

Want to read all 222 pages?

  • Fall '19
  • PCI Express, Fujitsu, PCI Expansion Unit

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture