Area as per design requirement Parking for Scooter Cycle Area as per design

Area as per design requirement parking for scooter

This preview shows page 58 - 63 out of 211 pages.

Area as per design requirement Parking for Scooter & Cycle Area as per design requirement Parking for Scooter & Cycle Area as per design requirement Parking for Scooter & Cycle Area as per design requirement 11 Single entry door should be card system next to reception
Image of page 58
Compendium of Central Government Services and Regulations for Greenfield Airport [59] CATEGORY-1 CATEGORY-2 CATEGORY-3 CATEGORY-4 12 Lift and staircase should be after entry through the access control door Area as per design requirement Lift and staircase should be after entry through the access control door Area as per design requirement Lift and staircase should be after entry through the access control door Area as per design requirement Provided 13 Caretaker room/Store 4M X 4M Caretaker room/Store 4M X 4M Caretaker room/Store 4M X 4M Nil B. CNS 1a EPABX 5M X 4M EPABX 5M X 4M EPABX 5M X 4M Provided in 2 nd Fl. 1b Battery room 5M X 3M Battery room 5M X 3M Battery room 5M X 3M Provided in 2 nd Fl. 2 CCTV equipment room 5M X 5M CCTV equipment room 5M X 5M CCTV equipment room 5M X 5M Nil C. ATC 1 Movement Liason unit (MLU) 5M X 5M Nil Nil Nil 2 Operational Office 5M X 6M Operational Office 5M X 6M Operational Office 5M X 5M Provided in 2 nd Fl. 3 Operational stores 4M X 4M Operational stores 4M X 4M Operational stores 4M X 4M Provided in 2 nd Fl. 4 Support room to Apron Control 5M X 5M Support room to Apron Control 5M X 5M Support room to Apron Control 5M X 5M Nil
Image of page 59
Compendium of Central Government Services and Regulations for Greenfield Airport [60] CATEGORY-1 CATEGORY-2 CATEGORY-3 CATEGORY-4 D. SECURITY E. INDIAN MET. DEPTT. Aerodrom Met. Offices (AMO) Hall with partitions 120 Sq.M. Aerodrom Met. Station (AMS) Hall with partitions 100 Sq.M. Aerodrom Met. Station (AMS) Hall with partitions 100 Sq.M. Nil a Officer incharge 5M X 5M Officer incharge 5M X 5M Officer incharge 5M X 5M Provided in 2 nd Fl. b PS 2.5M X 2M PS 2.5M X 2M Nil Communication room 8M X 8M Nil Nil Nil Instrument Maint. Room 5M X 5M Instrument Maint. Room 5M X 5M Instrument Maint. Room 5M X 5M Provided in 2 nd Fl. F. FIRE 1 4 Nos. CFT Parking Double height area 14.25 M X 6.5 M X 4Nos. 2 Reception, 2-Lifts, Staircase 14.25 M X 7.5 M 3 Crew room 5.5 M X 3.125 M (Facing Airside) 4 Store-1 5.5 M X 3.125 M 5 Foam Store 5.5 M X 3.125 M 6 S/R and Pantry 5.5 M X 3.125 M
Image of page 60
Compendium of Central Government Services and Regulations for Greenfield Airport [61] CATEGORY-1 CATEGORY-2 CATEGORY-3 CATEGORY-4 7 S/C office 5.5 M X 3.125 M 8 Control room 5.5 M X 3.125 M 9 Gents Toilet with bath 5.5 M X 6.25 M Note: 1. Provision of facilities i.e. ramp, wash rooms, railing, drinking water etc. for physically challenged persons to be provided at each floor. 2. Pantry to be provided at each floor having refrigerator, microwave, hot and cold water and hot case etc.
Image of page 61
Compendium of Central Government Services and Regulations for Greenfield Airport [62] Annexure STANDARD REQUIREMENTS FOR ATC CUM TECHNICAL BLOCK AT VARIOUS AIRPORTS CATEGORY-1 CATEGORY-2 CATEGORY-3 CATEGORY-4 FIRST FLOOR PLAN (All Centre line dimension) Sl.
Image of page 62
Image of page 63

You've reached the end of your free preview.

Want to read all 211 pages?

  • Winter '12
  • Air safety, Runway, Rajiv, Greenfield Airports, Central Government Services

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture