When the ampacity of the service entrance is to be increased and the service conduit already installed is adequate, then a meter socket shall be installed on the line side of the main switch. Where the existing metering facilities are located within the building and where the service conduit is being replaced or relocated, a meter socket shall be installed
Image of page 6

Subscribe to view the full document.

Commercial & Industrial Metering Guide Section 1 - Page 6 on the exterior of the building on the line side of the main switch. In such cases where power and lighting loads are metered separately, the two services shall be combined and supplied through one meter. 5.6 Meter Socket Connections 5.6.1 Single Phase 120 Volt 2 Wire Service The meter socket shall be of the 4-jaw type with the neutral connected to the right line terminal. For connection diagram, see Appendix B, Figure 1. 5.6.2 Single Phase 120/240 Volt 3 Wire Service The meter socket shall be of the 4-jaw type with the line conductors connected to the top terminals. The neutral shall be bonded in the centre of the socket with No. 6 AWG, insulated copper wire. For connection diagram, see Appendix B, Figure 2. 5.6.3 Network from a 120/208 Volt 3 Phase 4 Wire Wye System The meter socket shall be of the 5-jaw type with the neutral conductor connected to the 5th terminal located between the left-hand line and load terminals, at 9 o’clock position on the socket. This terminal shall be of the lay-in type or equivalent with the lug being large enough to accommodate the full size of the line conductor. For connection diagram, see Appendix B, Figure 3. 5.6.4 Three Phase 3 Wire Ungrounded Delta The meter socket shall be of the 5-jaw type with the centre or B phase conductor connected to the 5th terminal. This terminal shall be of the lay-in type or equivalent with the lug being large enough to accommodate the full size of the line conductor. For connection diagram, see Appendix B, Figure 4. 5.6.5 Three Phase 4 Wire Wye The meter socket shall have seven terminals, 7-jaw type. The neutral or grounded conductor terminal may be the lay-in type or terminated at a terminal block in the socket, with a NO. 6 AWG, insulated copper wire or bus bar connection being made to the neutral terminal for the meter. This conductor will be connected to the third from the left terminal on the load side of the meter socket. For connection diagram, see Appendix B, Figure 5.
Image of page 7
Commercial & Industrial Metering Guide Section 1 - Page 7 5.6.6 Three Phase 4 Wire Delta (120/240 Volt) The meter socket shall have seven terminals, 7-jaw type.. The neutral or grounded conductor terminal may be the lay-in or terminated at a terminal block in the socket, with a NO. 6 AWG, insulated copper wire or bus bar connection being made to the neutral terminal for the meter.
Image of page 8

Subscribe to view the full document.

Image of page 9
  • Spring '18
  • Three-phase electric power, Internet socket, meter sockets, Qulliq Energy Corporation, Meter Rings, Iqaluit Meter Shop

{[ snackBarMessage ]}

What students are saying

  • Left Quote Icon

    As a current student on this bumpy collegiate pathway, I stumbled upon Course Hero, where I can find study resources for nearly all my courses, get online help from tutors 24/7, and even share my old projects, papers, and lecture notes with other students.

    Student Picture

    Kiran Temple University Fox School of Business ‘17, Course Hero Intern

  • Left Quote Icon

    I cannot even describe how much Course Hero helped me this summer. It’s truly become something I can always rely on and help me. In the end, I was not only able to survive summer classes, but I was able to thrive thanks to Course Hero.

    Student Picture

    Dana University of Pennsylvania ‘17, Course Hero Intern

  • Left Quote Icon

    The ability to access any university’s resources through Course Hero proved invaluable in my case. I was behind on Tulane coursework and actually used UCLA’s materials to help me move forward and get everything together on time.

    Student Picture

    Jill Tulane University ‘16, Course Hero Intern