LOCATION ground levelSYSTEMHOMEINTRODUCTIONCONTACTSHVAC SYSTEMSVERTICAL TRANSPORTELECTRICAL SYSTEMSCOMMUNICATIONSFIRE SYSTEMSSTUDENTSTYPECOMPONENTS 1COMPONENTS 2LOCATIONAHUCHILLER ROOMCOOLING TOWERPUMP ROOMINSTALLATIONMAINTENANCEAREA + VOLUMECOOLING LOAD 1COOLING LOAD 2INTEGRATION
MELBOURNE EXHIBITION CENTREThe cooling tower is used in the HVAC system to reduce the water temperature after heat exchange takes place in the chiller component. The water is supplied to the cooling tower at around 35°C, it travels down through the ventilated core of the tower and cooled to around 28°C. whilst the temp drop is not high it is sufficient in transferring heat out of the cycle. Maintenance, monitoring and cleaning of the cooling towers is vital in ensuring quality running conditions. [refer previous pages]HVAC systemSYSTEM LOCATIONBuilding Environmental Services :Major AssignmentCOOLING TOWERLOCATION COOLING TOWER UNITDESIGNATED PLANT AREABOILER UNITS2 x 2900kwELECTRICAL SWITCH BOARDRETURN FLUID FROM CHILLERCOOLED FLUID TO CHILLEROPEN AIR ACCESSEXTERNAL AIR VENTILATIONACCESS VIA CRANE FOR UNIT INSTALLATION/REPLACEMENTLOUVERED WALL VENTILATION ACCESS TO ZONE top levelPLANT ROOM + BOILERThe plant zone contains boilers and other plant units including exhaust fans, kitchen equipment etc. The boilers are responsible for heating water to a high temperature to be used for various functions around the building. The HVAC system primarily uses the HHW [boiler water] in the AHU to heat supply air, however other applications include supply heat for the hot water services etc.COOLING TOWERSYSTEMHOMEINTRODUCTIONCONTACTSHVAC SYSTEMSVERTICAL TRANSPORTELECTRICAL SYSTEMSCOMMUNICATIONSFIRE SYSTEMSSTUDENTSTYPECOMPONENTS 1COMPONENTS 2LOCATIONAHUCHILLER ROOMCOOLING TOWERPUMP ROOMINSTALLATIONMAINTENANCEAREA + VOLUMECOOLING LOAD 1COOLING LOAD 2INTEGRATION
PUMP UNITSFLUID FROM CHILLERFLUID PUMPED TO AHUINSULATED PIPE SYSTEMACCESS TO FIRE ROOMACCESS TO CHILLER ROOMACCESS TO SWITCH BOARD ROOMMELBOURNE EXHIBITION CENTREPUMP ROOMThe size of the Exhibition centre means that there is a large distance between the chillers and the AHU’s.The pump room is therefore a vital element in insuring the heat/chilled water supply to the AHU.The flow and return pipe circuit run via the pipe riser in the Clarendon zone behind lift one to the top floor. They also travel the length of the exhibition area in the basement service area.HVAC systemSYSTEM LOCATIONBuilding Environmental Services :Major AssignmentPUMP ROOMLOCATION PUMP SWITCHBOARD*note. The pump room occupies a large area. Firstly due to the number of pumps and secondly to allow circulation room and areas for maintenance and access to the pumps and surrounding service rooms.

Upload your study docs or become a

Course Hero member to access this document

Upload your study docs or become a

Course Hero member to access this document

End of preview. Want to read all 56 pages?

Upload your study docs or become a

Course Hero member to access this document

Term
One
Professor
N/A
Tags
MEC Melbourne Exhibition Centre

Newly uploaded documents

Show More

Newly uploaded documents

Show More

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture