DA09 – Table 37Air Films HorizontallyDownWinter0.107DA09 – Table 37Air Films HorizontallyUpOutside AirSummer0.044DA09 – Table 37Air Films HorizontallyDownWinter0.03DA09 – Table 37Air Films HorizontallyUpTotal R-ValueSummer3.619Winter3.551Total U-valueSummer0.276Winter0.2817
Background image
U-value for Walls made from different materials: Step 1:Understanding the alignment of the materials in the wall.Step 2:Finding the R-value of each material.Step 3:Compiling all the ones in series like Σ R=R1+R2+R3….+RnStep 4:Compiling all the ones is parallel like Σ1R=1R1+1R2+1R3++1RnStep 5:Compiling both as per the given information: Σ R=R(outsideair)+R(Plaster)+(1R(woodenrafter)+1R(fibre glass)+1R(woodenrafter))+R(woodendeck)+Table 5BuildingSectionConstructionMaterialArea(m2)Density(Kg/m3)Thickness(m)SurfaceDensity(Kg/m2)U-Value(W/m2K)ReferencesFloorConcrete + Sand Topping + Carpet Underlay141.7522960.1252871.22 (summer)1.38 (winter)DA09 – Table 27,28CeilingWood Rafter + Plaster + Fibreglass insulation + Wooden Roof Deck + Metal Decking141.75169210.215654.60.27 (summer)0.28 (winter)DA09 – Table 37North WallBrick + Plaster40.520700.2752401.66 (summer)1.7 (winter)DA09 – Table 25,37North WindowGlass Sheet93364.50.00620.25.05 (summer)6.36 (winter)DA09 – Table 37West WallPlaster Board70.87588.70.124111.78DA09 – Table 26South WallPlaster Board70.87588.70.124111.78DA09 – Table 26East Plaster Board70.8788.70.124111.78DA09 – 8
Background image
Wall5Table 262.1.3 U AND R-VALUES FOR SHOP MM03Table 6BuildingSectionConstructionMaterialArea(m2)Density(Kg/m3)Thickness(m)SurfaceDensity(Kg/m2)U-Value(W/m2K)ReferencesFloorConcrete + sandtopping + carpetand underlay44022960.1252871.22(summer)1.38(winter)DA09Table27,28CeilingBituminous felt roof with concrete and sand and cementtopping44025360.1253171.77(summer)2.03(winter)DA09Table29,30NorthWallBrick + Plaster(gypsum)89.420700.275569.31.81(summer)1.86(winter)DA09Table25,37NorthWindowGlass sheet93364.50.00620.25.05(summer)6.36(winter)DA09Table 37EastWallBrick + Plaster(gypsum)114.820700.275569.31.81(summer)1.86(winter)DA09Table25,37EastWindowGlass sheet93364.50.00620.25.05(summer)6.36(winter)DA09Table 37WestWall 1Plasterboard +air gaps70.988.70.124111.78DA09Table 26WestWall 2Plasterboard +air gaps43.988.70.124111.78DA09Table 26SouthWall 1Plasterboard +air gaps5488.70.124111.78DA09Table 26SouthWall 2Plasterboard +air gaps33.888.70.124111.78DA09Table 26Now summarizing the tables above into a more direct and simple table:SHOP T06Table 7COMPONENTSSUMMERR-VALUESUMMER U-VALUEWINTERR-VALUESUMMERU-VALUEFloor0.811.220.721.38Ceiling3.610.273.550.28North Wall0.61.660.581.7North Window0.1985.050.1576.36West Wall0.561.780.561.78South Wall0.561.780.561.78East Wall0.561.780.561.789
Background image
SHOP MM03Table 8COMPONENTSSUMMERR-VALUESUMMERU-VALUEWINTERR-VALUEWINTERU-VALUEFloor0.811.220.721.38Ceiling0.561.770.492.03North Wall0.551.810.531.86North Window0.1985.050.1576.36East Wall0.551.810.531.86East Window0.1985.050.1576.36West Wall 10.561.780.561.78West Wall 20.561.780.561.78South Wall 10.561.780.561.78South Wall 20.561.780.561.78After getting the U and R values for both the shops, the minimum required R values need to bechecked using the NCC Volume One 2016 (assuming that the minimum R values given in theassignment aren’t true).