VENT TERMINATION
VSTR shall
terminate
vertically
not
less
than
150
mm above the roof nor less than
0.3 meter from
any vertical
surface
nearby.

VENT TERMINATION
Each
vent
opening
shall terminate;
•
Not less than three
(3)
meters
from any
openable window
•
Not less than
0.9 meter
above any
openable
window
•
Not less than
0.9 meter
above any
lot line ,
alley, and street
boundary line.

VENT TERMIINATION
Vertical vent pipes shall extend 3.00 m distant from
any part of the roof that is used for human activities
and shall extend not less than 2.10 m above such
roof.

VENT TERMINATION
Flagpoling of vent is prohibited.

VENT TERMINATION
Joint at the roof around stack unit pipes shall be
made watertight.

RELIEF VENT AND YOKE VENT
10TH FLOOR
•
Each
soil or
waste
stack
which
extends
ten
(10)
or
more
stories
above
the
building drain
shall be
served by a parallel vent
stack . It shall connect
to
the soil or waste
stack
at
ground
level
and
at
every fifth
floor levels
with
a “yoke vent"