VENT TERMINATION VSTR shall terminate vertically not less than 150 mm above the

Vent termination vstr shall terminate vertically not

This preview shows page 17 - 23 out of 23 pages.

VENT TERMINATION VSTR shall terminate vertically not less than 150 mm above the roof nor less than 0.3 meter from any vertical surface nearby.
Image of page 17
VENT TERMINATION Each vent opening shall terminate; Not less than three (3) meters from any openable window Not less than 0.9 meter above any openable window Not less than 0.9 meter above any lot line , alley, and street boundary line.
Image of page 18
VENT TERMIINATION Vertical vent pipes shall extend 3.00 m distant from any part of the roof that is used for human activities and shall extend not less than 2.10 m above such roof.
Image of page 19
VENT TERMINATION Flagpoling of vent is prohibited.
Image of page 20
VENT TERMINATION Joint at the roof around stack unit pipes shall be made watertight.
Image of page 21
RELIEF VENT AND YOKE VENT 10TH FLOOR Each soil or waste stack which extends ten (10) or more stories above the building drain shall be served by a parallel vent stack . It shall connect to the soil or waste stack at ground level and at every fifth floor levels with a “yoke vent"
Image of page 22
Image of page 23