the UK on the other hand although some large organizations have separate

The uk on the other hand although some large

This preview shows page 14 - 17 out of 56 pages.

the UK on the other hand, although some large organizations have separate specifications for their own use many adopt the available British Standards and only add any requirement necessary for their purposes. Cables and Flexible Records IEC 55 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminum conductors and excluding gas pressure and oil-filled cables) 55-1 Part 1 Tests 55-2 Part 2 Construction Insulation and Sheathing (non-metallic) IEC 446 Identification of insulated and bare conductors by color Tests on Cables and Materials IEC 55 Similar to BS EN 60811. Insulating and sheathing materials of electric cables - Common test methods BS EN 60811-1 General application BS EN 60811-1-1: 1995 Measurement of thickness and overall dimensions - Tests for determining the mechanical properties BS EN 60811-1-2: 1995 Thermal ageing methods PE4| Group 5_5EEB
Image of page 14
UNIVERSITY OF SANTO TOMAS FACULTY OF ENGINEERING España, Manila BS EN 60811-1- 3:1995 Methods for determining the density - Water absorption tests - Shrinkage test BS EN 60811-1- 4:1995 Tests at low temperatures BS EN 60811-2 Methods specific to elastomeric compounds BS EN 60811-2- 1:1995 Ozone resistance test - Hot set test- Mineral oil immersion test BS EN 60811-3 Methods specific to PVC compounds BS EN 60811-3- 1:1995 Pressure test at high temperature - Tests for resistance to cracking BS EN 60811-3- 2:1995 Loss of mass test - Thermal stability test BS EN 60811-4: Methods specific to polyethylene and polypropylene compounds BS EN 60811-4- 1:1995 Resistance to environmental stress cracking Wrapping test after thermal ageing in air - Measurement of the melt flow index – Carbon black and/or mineral content measurement in PE IEC 60 High voltage test techniques 60-1 Part 1 General definitions and test requirements 60-2 Part 2 Test procedures 60-3 Part 3 Measuring devices 60-4 Part 4 Application guide for measuring devices IEC 141 Tests on oil-filled and gas pressure cable and their accessories 141-1 Part 1 Oil-filled, paper-insulated, metal-sheathed cables for alternating voltages up to and including 400 kV 141-2 Part 2 Internal gas pressure cables and accessories for alternating voltages up to and including 275 kV 141-3 Part 3 External gas pressure (gas compression) cables and accessories for alternating voltages up to 275 PE4| Group 5_5EEB
Image of page 15
UNIVERSITY OF SANTO TOMAS FACULTY OF ENGINEERING España, Manila kV 141-4 Part 4 Oil-impregnated paper-insulated high-pressure oil-filled pipe-type cables and accessories for alternating voltages up to and including 400 kV IEC 229 Tests on cable over sheaths which have a special protective function and are applied by extrusion IEC 230 Impulse tests on cables and their accessories IEC 332 Tests on electric cables under fire conditions 332-1 Part 1 Test in a single vertical insulated copper wire of cable 332-2 Part 2 Test on a single small vertical insulated copper wire or cable 332-2 Part 3 Tests on bunched wires or cables IEC 538 Electric cables, wires, and cords: methods of test for polyethylene insulation and sheath IEC 540 Test methods for insulation and sheaths of electric cables and cords
Image of page 16
Image of page 17