obtained by the same procedure refer to Figures-22,23. 
Image of page 27
Surface West Wall (213) (Brick) North Wall (213) West Wall (213) (glass part) Floor (213) ( MO2) A (m2) 67.500 67.500 63.000 435.000 U-value 1.706 1.542 5.893 0.236 Out Door 24 24 24 22 In door 24 24 24 24 Delta T 0 0 0 2 Q 0.000 0.000 0.000 205.161 Total Summer External heat loads for partition SHOP-213 205.161 Summer Figure 22 Winter Partition external load calculations for shop-213 Surface West Wall (213) (Brick part) West Wall (213) (Window Part ) North Wall (213) Floor (213) (al above MO2) A 225 210 90 435 U-value 1.709257065 6.422607579 1.598594503 0.312249579 Out Door 21 21 21 20 In door 21 21 21 21 delta T 0 0 0 -1 Q 0 0 0 -135.8285667 Total Winter External heat loads for partition SHOP-213 -135.8285667 Figure 23 Winter Partition External Load Calculation for Shop-213 CHAPTER 5 5.1 External Load Calculation in Winter for Shop-212,213 The external loads calculation varies from winter to summer. In summer, the calculations tend to  encounter solar transmission where a significant amount of heat disturbs the cooling in as such  complex. Whilst, in heating load the solar transmission will be neglected since the peak time of  the day almost at the very morning where the sun does not yet arise. 
Image of page 28
External surfaces East wall (212) East wall (213) South wall (213) Roof (213) Roof (212) Reference U 0.398406375 0.39840637 0.52910053 0.31224958 0.31224958 A 156 174 90 435 390 Outside Temp. 2.1 2.1 2.1 2.1 2.1 design condition Inside Temp 21 21 21 21 21 Delta t -18.9 -18.9 -18.9 -18.9 -18.9 Heat load -1174.661355 -1310.1992 -900 -2567.1599 -2301.5916 Total external wall heat load in winter (w) Total for shop-212 -3476.253 Total for shop-212 -4777.3591 Winter (External wall heat load) Figure 24 External wall head load calculation Also, the glazing heat load should be identified following the same procedure as shown in  Figure-45.  External surfaces East (212) East (213) South (213) Reference U 5.892751915 5.89275192 5.89275192 A 52 58 26 Temp outside 2.1 2.1 2.1 Temp inside 21 21 21 Delta t -18.9 -18.9 -18.9 Heat load -5791.396582 -6459.6346 -2895.69829 Total external glazing heat load in winter (w) -5791.396582 Winter (glazing heat load) -9355.33294 Figure 25 Glazing head load calculation CHAPTER 6 6.1 Internal Loads Calculation in Summer for Shop-212
Image of page 29
Image of page 30
Image of page 31

You've reached the end of your free preview.

Want to read all 43 pages?

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture