flush urinal during a power outage Stadium Feature Valve automatically switches

Flush urinal during a power outage stadium feature

This preview shows page 27 - 30 out of 30 pages.

flush urinal during a power outage • Stadium Feature: Valve automatically switches to water conservation mode during periods of heavy usage • Range can be adjusted manually or by remote control • Sensor & electronic controls are fully enclosed and water resistant • Automatically flushes after 24 hours of non-use to maintain trap seal • 3-second Flush Delay • Low Battery indicator • Battery can be changed without turning off the water • Factory-installed 6V lithium battery included • Adjustable tailpiece for rough-in flexibility • Can be installed left or right hand • Battery life up to 4 years/approx. 200,000 cycles • Model 6063.013 for 3/4" top spud urinals, 0.125 gpf Includes: • 2 Wall hangers • 3/4" I.P.S. angle stop with back-flow protection and vandal-resistant cap • Sweat solder kit including cover tube and wall flange • 3/4" vacuum breaker, spud coupling and flange High-Efficiency Urinal Systems: • 87.5% water savings when compared to a 1.0 gpf urinal system Operating Pressure: Overall Range: 20-125 psi** Recommended: 20 psi (flowing)-80 psi (static) ** Water pressure over 80 psi is not recommended for most plumbing fixtures. Flow Requirement: 10 gpm (37.9 L/min.) Nominal Fixture Dimensions: 360 x 480 x 664mm (14-1/8" x 18-7/8" x 26-1/8")
Image of page 27
N24 © 2014 AS America Inc. Rev. 6/14 WASHBROOK ® FloWise ® 0.125 GPF ULTRA HIGH EFFICIENCY URINAL SYSTEM SELECTRONIC ® FLUSH VALVE MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES - CHECK LOCAL CODES. When installed so top of rim is 387mm (15-1/4") from finished floor. NOTES: PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. IMPORTANT : Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. 13mm (1/2") 102mm (4") GASKET 2" N.P.T. INSIDE THREADS DETAIL OF OUTLET CONNECTION FINISHED WALL 13mm (1/2") FINISHED WALL *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be a minimum of 6" (152mm) above fixture. Consult Codes for details. VALVE LEFT or RIGHT HAND INSTALLATION SUPPLY DN 20mm (3/4" I.P.S.) 64mm (2-1/2" MIN.) DETECTION ZONE 400mm-800mm (15-3/4" TO 31-1/2") 15˚ 115-133mm (4-1/2" to 5-1/4") 409mm (16-1/8") 293mm (11-1/2") MANUAL OVERRIDE BUTTON *CRITICAL LEVEL -C-L- 438mm (17-1/4") 664mm (26-1/8") REF. 464mm (18-1/4") 83mm (3-1/4") 102mm (4") 480mm (18-7/8") 343mm (13-1/2") C/L OF OUTLET K2 HANGERS 8mm X 25mm (5/16" X 1") SLOT 235mm (9-1/4") 360mm (14-1/8") 2" N.P.T. FEMALE OUTLET CONNECTION 13mm (1/2") FINISHED FLOOR 387mm (15-1/4") MAX 610mm (24") OPTIONAL Fixture Compliance Certifications - Meets or Exceeds the Following Specifications: • ASME A112.19.2-2008/CSA B45.1-08 for Vitreous China Fixtures Valve Listings: • ASSE 1037 • ANSI/ASME A112.19.2 • ADA Compliant
Image of page 28
N121 © 2014 AS America Inc. 7/14 To Be Specified: Color: White Seat: American Standard #5901.100 Heavy duty open front less cover American Standard #5905.100 Extra heavy duty open front less cover AFWALL ® MILLENIUM FloWise ® 1.28 GPF FLUSHOMETER TOILET SYSTEM less EVERCLEAN ® SELECTRONIC ® EXPOSED AC FLUSH VALVE AFWALL ® MILLENIUM™ FloWise ® 1.28 GPF
Image of page 29
Image of page 30

You've reached the end of your free preview.

Want to read all 30 pages?

  • Fall '10
  • SCHNEIDER

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture