contents out BLOW OUT 429 A basin like fixture design to be struddled for

Contents out blow out 429 a basin like fixture design

This preview shows page 17 - 19 out of 27 pages.

contents out BLOW OUT 429 A basin like fixture design to be struddled for bathing the genitals and posterior parts of the body BIDET 430 1/2", 3/4", 1", 1 1/4", 1 1/2", 2, 2 1/2", 3", 4", 6", 8", 10", 12" GI PIPE SIZES 431 No building supply pipe shall be less than WHAT size in diameter 19.05mm or 3/4" 432 Minimum height of Fire Service Connection from the grade/floor 46 cm. 433 Maximum height of Fire Service Connection from the grade/floor 122cm 434 Minimum height of Dry Standpipe Outlet from the floor line 61 cm. 435 Maximum height of Dry Standpipe Outlet from the floor line 122 cm 436 Considered extension of bulding drain outside the building wall 5 FEET 437 Fitting for base or soil stack and building drain 1/4" BEND ? 438 Wet standpipe for a riser not more than 15m 51mm or 2" 439 Wet standpipe for riser more than 15m 64mm or 2 1/2" 440 Dry standpipe for a riser below 23m 4" 441 Dry standpipe for a riser more than 23m 6" 442 Ratio of water closets for female population for elementary and secondary school RATIO OF 1:25 443 Ratio of water closets for male population for elementary and secondary school RATIO OF 1:30 444 Ratio of urinals for elementary schools RATIO OF 1:75 445 Ratio of water closets for female population for principal worship places RATIO OF 1:75 446 Ratio of lavatory to number of occupants RATIO OF 1:5 447 Minimum number of water closet required for female office and public buildings 4 CLOSETS 448 Minimum head of water required in section of plumbing for water test 3 HEADS 449 It should not be used for steam GALVANIZED PIPING 450 High Pressure WHITE 451 Exhaust Fan BUFF 452 Fresh Water, low pressure BLUE 453 Fresh Water, high pressure BLUE 454 Salt water piping GREEN 17/27
Image of page 17
PLUMBING REVIEWER 455 Oil Delivery BRASS OR BRONZE 456 Oil Discharge YELLOW 457 PNEUMATIC DIVISION GRAY 458 GAS DIVISION BLACK 459 FUEL OIL DIVISION BLACK 460 REFRIGERATING DIVISION BLACK 461 A full open type valve is used in several locations in a water distribution system, which of the following does NOT require it? ON EVERY HOSE BIBB462A fireline system without a constant water supply and is equipped with a fire service inlet and outlet connection installed exclusively for the use of Fire ServiceDRY STANDPIPE463Term used to main water pipe delivering portable water to a buildingWATER SERVICE PIPE464 Which poor design in the plumbing system causes water supply drop when the fixture is simultaneously opened? INSUFFICIENCY IN THE SIZE OF THE WATER SERVICE AND DISTRIBUTION PIPE 465 KITCHEN SINK TRAP SIZE 1 ½" 466 LAVATORY TRAP OR BRANCH SIZE 1 ¼" 467 OUTLET OF DRY STANDPIPE 64mm or 2 ½" 468 OUTLET OF WET STANDPIPE for riser of more than 15 mts 64mm or 2 ½" 469 Not needed in sizing the vent pipe for individual branch and circuit vent based on the total linear footage of the pipe making up the vent? SLOPE OF THE DRAIN PIPE 470 A hot and cold water supply pipes, where it is mix manually in desired water temperature temperature and direct the mixed water either at the shower head or at the fooe spout 3 WAY VALVE DIVERTER 471 Principle where a single lever valve used in kitchen sink and lavatory, they are beautiful and maintenance free BALL VALVE 472 Minimum water delivery in liters per minute for an outlet of a wet standpipe
Image of page 18
Image of page 19

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture

  • Left Quote Icon

    Student Picture