contents out
BLOW OUT
429
A basin like fixture design to be struddled for bathing the genitals and posterior parts of
the body
BIDET
430
1/2", 3/4", 1", 1 1/4", 1 1/2", 2, 2 1/2",
3", 4", 6", 8", 10", 12"
GI PIPE SIZES
431
No building supply pipe shall be less than WHAT size in diameter
19.05mm or 3/4"
432
Minimum height of Fire Service Connection from the grade/floor
46 cm.
433
Maximum height of Fire Service Connection from the grade/floor
122cm
434
Minimum height of Dry Standpipe Outlet from the floor line
61 cm.
435
Maximum height of Dry Standpipe Outlet from the floor line
122 cm
436
Considered extension of bulding drain outside the building wall
5 FEET
437
Fitting for base or soil stack and building drain
1/4" BEND ?
438
Wet standpipe for a riser not more than 15m
51mm or 2"
439
Wet standpipe for riser more than 15m
64mm or 2 1/2"
440
Dry standpipe for a riser below 23m
4"
441
Dry standpipe for a riser more than 23m
6"
442
Ratio of water closets for female population for elementary and secondary school
RATIO OF 1:25
443
Ratio of water closets for male population for elementary and secondary school
RATIO OF 1:30
444
Ratio of urinals for elementary schools
RATIO OF 1:75
445
Ratio of water closets for female population for principal worship places
RATIO OF 1:75
446
Ratio of lavatory to number of occupants
RATIO OF 1:5
447
Minimum number of water closet required for female office and public buildings
4 CLOSETS
448
Minimum head of water required in section of plumbing for water test
3 HEADS
449
It should not be used for steam
GALVANIZED PIPING
450
High Pressure
WHITE
451
Exhaust Fan
BUFF
452
Fresh Water, low pressure
BLUE
453
Fresh Water, high pressure
BLUE
454
Salt water piping
GREEN
17/27

PLUMBING
REVIEWER
455
Oil Delivery
BRASS OR BRONZE
456
Oil Discharge
YELLOW
457
PNEUMATIC DIVISION
GRAY
458
GAS DIVISION
BLACK
459
FUEL OIL DIVISION
BLACK
460
REFRIGERATING DIVISION
BLACK
461
A full open type valve is used in several locations in a water distribution system, which of the following does NOT require it?
ON EVERY HOSE BIBB462A fireline system without a constant water supply and is equipped with a fire service inlet and outlet connection installed exclusively for the use of Fire ServiceDRY STANDPIPE463Term used to main water pipe delivering portable water to a buildingWATER SERVICE PIPE464
Which poor design in the plumbing system causes water supply drop when the fixture is simultaneously opened?
INSUFFICIENCY IN THE SIZE
OF THE WATER SERVICE AND
DISTRIBUTION PIPE
465
KITCHEN SINK TRAP SIZE
1 ½"
466
LAVATORY
TRAP OR BRANCH SIZE
1 ¼"
467
OUTLET OF DRY STANDPIPE
64mm or 2 ½"
468
OUTLET OF WET STANDPIPE for riser of more than 15 mts
64mm or 2 ½"
469
Not needed in sizing the vent pipe for individual branch and circuit vent
based on the
total linear footage of the pipe making up the vent?
SLOPE OF THE DRAIN PIPE
470
A hot and cold water supply pipes, where it is mix manually in desired water temperature
temperature and direct the mixed water either at the shower head or at the fooe spout
3 WAY VALVE DIVERTER
471
Principle where a single lever valve used in kitchen sink and lavatory, they are
beautiful
and maintenance free
BALL VALVE
472
Minimum water delivery in liters per minute for an outlet of a wet standpipe