Calculate and check the design strength of the connection shown below.Assume:Assume A325 bolts (Fy=620 MPa)
Mechanical properties of plate Fy= 248 MPa Fu= 399.8 MPa
Notice that, you have control Shear strength of bolts, and Bearing strength of plate at bolt holes.
Image transcriptions
Calculate and check the design strength of the connection shown below. Assume: Assume A325 bolts (Fy=620 MPa) Mechanical properties of plate Fy= 248 MPa Fu= 399.8 MPa Notice that, you have control Shear strength of bolts, and Bearing strength of plate at bolt holes] Plate 18mm A36 Plate 150 * 12mm 40 A36 80 O Tensile Force mm 40 19 mm bolts (Diameter) H 40 80 40 mm All dimension are in mm