Calculate and check the design strength of the connection shown below. Assume: Assume A325 bolts (Fy=620 MPa) Mechanical properties of plate Fy= 248...
This question has been answered
Question

Calculate and check the design strength of the connection shown below.Assume:Assume A325 bolts (Fy=620 MPa)

Mechanical properties of plate Fy= 248 MPa Fu= 399.8 MPa


Notice that, you have control Shear strength of bolts, and Bearing strength of plate at bolt holes.21321.jpg

Image transcriptions

Calculate and check the design strength of the connection shown below. Assume: Assume A325 bolts (Fy=620 MPa) Mechanical properties of plate Fy= 248 MPa Fu= 399.8 MPa Notice that, you have control Shear strength of bolts, and Bearing strength of plate at bolt holes] Plate 18mm A36 Plate 150 * 12mm 40 A36 80 O Tensile Force mm 40 19 mm bolts (Diameter) H 40 80 40 mm All dimension are in mm

Answered by Expert Tutors
Step-by-step explanation
1 Attachment
IMG_20201213_091656.JPG
JPG
Get unstuck

426,507 students got unstuck by Course
Hero in the last week

step by step solutions

Our Expert Tutors provide step by step solutions to help you excel in your courses